| CR10 The 
              composite floor, which acts as a diaphragm structure which 
              provides rigidity to the vertical steel members, is constructed of 
              reinforced concrete laid on a ribbed steel deck as a permanent 
              shutter. The one shown here is the deck prior to placement of the 
              floor reinforcement.  
                
                 
             |